MClimate LoRaWAN Devices
  • Overview
  • FAQ
  • Firmware Upgrade Over The Air (FUOTA)
  • Devices
    • 🆕МClimate 16A Dry Switch (16ADS)
      • 🥳Release notes
      • 🛠️How to use
      • ⬆️MClimate 16ADS Uplink decoder
      • ⬇️MClimate 16ADS Downlink encoder
      • 📖MClimate 16ADS Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • Overheating protection
        • Relay state 16ADS
        • LED indication mode
        • Network-related settings
        • Get Firmware & Hardware version
        • Restart device
    • 🆕МClimate 16A Switch & Power Meter LoRaWAN (16ASPM)
      • 🥳Release notes
      • 🛠️How to use
      • ⬆️MClimate 16ASPM Uplink decoder
      • ⬇️MClimate 16ASPM Downlink encoder
      • 📖MClimate 16ASPM Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • Protections
        • Relay state 16ASPM
        • Clear accumulated energy
        • LED indication mode
        • Network-related settings
        • Get Firmware & Hardware version
        • Restart device
    • 😲MClimate Fan Coil Thermostat (FCT)
      • 🥳Release notes
      • ⭐Getting started
      • ⚡Wiring Diagrams (Applications) & Operational Modes
      • ⬆️MClimate Fan Coil Thermostat Uplink decoder
      • ⬇️MClimate Fan Coil Thermostat Downlink encoder
      • 📖MClimate Fan Coil Thermostat Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Keep-alive
        • ON/OFF & Target temperature
          • Valve(s) operation
          • Target temperature ranges
        • Fan Settings
          • Auto Fan - Δ settings
        • 🔓Keys lock
        • External temperature measurement
        • Power module communication status
        • Function of digital input/output (IO1 and IO2 ports)
          • Automatic changeover
          • Occupancy sensor
        • General, Display & Power recovery
          • Hiding data from the display & settings
          • Frost Protection
          • Temperature sensor errors
          • Network-related settings
            • Uplink types
          • User interface language
        • Restart device
    • ♨️MClimate Vicki LoRaWAN
      • 🥳Release notes
      • ⬆️Vicki Uplink Decoder
      • ⬇️Vicki Downlink Encoder
      • 📖Vicki LoRaWAN Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • Manual target temperature change
        • Operational modes & temperature control algorithms
          • Algorithm 1 - Equal directional control
          • Algorithm 2 - Proportional control
          • Algorithm 3 - Proportional Integral
        • External temperature measurement and internal temperature offset
        • Control target temperature and/or motor position and range
        • Recalibrate motor command explanation
        • Read device hardware and software version command explanation.
        • Anti-freeze functionality
        • Open window detection
        • Child lock
        • Target temperature ranges
        • Temperature units
        • Force-close & Force-attach
        • Network-related settings
        • Appendix (examples)
      • 📺Technical Deepdive Webinar
    • 🆕MClimate CO2 Display lite
      • 🥳Release notes
      • ⬆️MClimate CO2 Display lite Uplink decoder
      • 📖CO2 Display lite Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • CO2 measurement settings
        • Hiding data from the display
        • Child lock
        • Network-related settings & Others
        • Get Firmware & Hardware version
        • Restart device
    • MClimate CO2 Display
      • 🥳Release notes
      • ⬆️MClimate CO2 Display Uplink decoder
      • 📖CO2 Display Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • CO2 measurement settings
        • Hiding data from the display
        • Child lock
        • PIR (Motion sensor)
        • Network-related settings & Others
        • Get Firmware & Hardware version
    • MClimate Wireless Thermostat
      • 🥳Release notes
      • ⬆️MClimate Wireless Thermostat Uplink decoder
      • ⬇️MClimate Wireless Thermostat Uplink encoder
      • 📖Wireless Thermostat Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • Target Temperature & Temperature range
        • Sensor mode & hiding data from the display
        • Heating status flag
        • Child lock
        • PIR (Motion sensor)
        • Get Firmware & Hardware version
        • Network-related settings & Others
    • MClimate HT Sensor LoRaWAN
      • 🥳Release notes
      • ⬆️HT Sensor Uplink Decoder
      • 📖HT Sensor LoRaWAN Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Temperature and humidity compensation
        • Keep-alive
        • Read device hardware and software version command explanation.
        • Network-related settings
        • Uplink types
        • Appendix (examples)
    • MClimate CO2 Sensor and Notifier LoRaWAN
      • 🥳Release notes
      • ⬆️CO2 Sensor Uplink Decoder
      • 📖CO2 Sensor LoRaWAN Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Keep-alive
        • Read device hardware and software version command explanation.
        • Network-related settings
        • Uplink types
        • CO2 boundary levels
        • CO2 auto-zero value
        • CO2 auto-zero period
        • CO2 Measurement period
        • Notifications configuration
    • MClimate Open/Close Sensor LoRaWAN
      • 🥳Release notes
      • ⬆️Open/Close Sensor uplink decoder
      • 📖Open/Close sensor LoRaWAN communication protocol
        • Commands cheat sheet
        • Keep-alive
        • Read device hardware and software version command explanation
        • Uplink types
        • Network-related settings
        • Event notification
        • Notification Blind Time
        • LED control command explanation
        • Restart device
    • MClimate Multipurpose Button LoRaWAN
      • 🥳Release notes
      • ⬆️Multipurpose Button Uplink decoder
      • 📖MClimate Button LoRaWAN Device communication protocol
        • Commands cheat sheet
        • Keep-alive
        • LEDs, button press types and behaviour
        • Read device hardware and software version command explanation
        • Network-related settings
        • Uplink types
        • Button press event counters
        • LED control command explanation
        • Restart device
    • MClimate T-Valve LoRaWAN
      • 🥳Release notes
      • ⬆️T-Valve Uplink Decoder
      • T-Valve LoRaWAN communication protocol
        • Commands cheat sheet
        • Uplink types
        • Keep-alive
        • Valve state control
        • Set LED behavior
        • Buzzer control
        • Emergency openings
        • Enable/disable manual valve open/close
        • Flood alarm time
        • Keep-alive period
        • Request Long data packet
        • Device allowed working voltage
        • Enable/Disable device flood sensor
        • Network related settings
        • Deactivate device (non-operational mode, save power)
    • MClimate Flood Sensor LoRaWAN
      • 🥳Release notes
      • ⬆️Flood Sensor Uplink Decoder
      • 📖Flood Sensor LoRaWAN communication protocol
        • Commands cheat sheet
        • Keep-alive
        • Flood event - Available configurations
        • Uplink types
        • Network-related settings
        • Read Firmware & Hardware version
        • Custom control of LED and Acoustic Buzzer
        • Read device parameters command
        • Restart device
    • MClimate AQI Sensor and Notifier LoRaWAN
      • 🥳Release notes
      • AQI Sensor Uplink Decoder
      • AQI Sensor Downlink encoder
      • AQI Sensor LoRaWAN Device communication protocol
        • Communication concepts
        • Commands cheat sheet
        • Keep-alive
        • Read device hardware and software version command explanation.
        • Network-related settings
        • Uplink types
        • Device buzzer control command
        • Device LED’s control
        • Appendix (examples)
  • Others
    • Application of MClimate Vicki to One-pipe steam heating systems
    • Battery Lifetime Estimation Methodology
    • Discover Smart Buildings solutions
    • How to solve Large space heating issues
    • Device Firmware upgrade via a Field Programming Kit (FPK)
      • Vicki Firmware Upgrade
  • Integrations
    • The Things Industries / TTN V3
    • ThingPark Enterprise
    • ThingPark Community
    • Tektelic
    • Helium
    • Chirpstack
    • Loriot
    • Kerlink
    • Melita
    • MachineQ
    • Orbiwise
    • Firefly
    • B-One
    • Milesight
    • Akenza
    • Element-IoT
    • Senet
    • Wattsense
    • RAK WisGateOS2
    • Netmore
Powered by GitBook
On this page
  • General Information
  • Power supply
  • Output circuit rating
  • Safety functions
  • Supported load types
  • Radio / Wireless
  • Sensors
  • Temperature sensor
  • Wiring diagram
  • Placement Guidelines

Was this helpful?

  1. Devices

МClimate 16A Dry Switch (16ADS)

PreviousFirmware Upgrade Over The Air (FUOTA)NextRelease notes

Last updated 6 months ago

Was this helpful?

General Information

The МClimate 16ADS is a miniature device that features a 16A dry relay. The device is small enough to fit behind most wall switches and outlets. The device operates in LoRaWAN Class C, features FUOTA (Firmware Upgrades Over The Air) and has overheating protection

Learn more about MClimate Smart Building Solutions:

Power supply

  • Mains powered

    • Voltage range - 100-240VAC / 24-30VDC

    • Consumption - 50mA

Output circuit rating

  • Max. switching voltage - 240VAC / 30VDC

  • Max. switching current - 16A AC (8A AC for cosφ=0.4 cos \varphi = 0.4 cosφ=0.4) / 10A DC

  • Max. switching power - 3840 (2000W for cosφ=0.4 cos \varphi = 0.4 cosφ=0.4) / 300W DC

Safety functions

  • Overheating protection

Supported load types

  • Resistive - incandescent bulbs, heating devices

  • Capacitive - capacitor banks, electronic equipment, motor start capacitors

  • Inductive - LED light drivers, transformers, fans, refrigerators, air-conditioners

Radio / Wireless

  • Wireless technology - LoRaWAN 1.0.3

  • Wireless security - LoRaWAN End-to-end encryption (AES-CTR)

  • LoRaWAN device type - Class C End-device

  • Supported LoRaWAN features - OTAA, ADR, Adaptive Channels setup

  • Supported LoRaWAN regions - EU868 - 870; Other LoRaWAN regional settings available upon request

  • Link budget - 130dB

  • RF transmit power - 14dB

Sensors

Temperature sensor

  • Resolution: 0,1°C

  • Accuracy: ±0,2°C (typ) - ±0,7°C (max)

Wiring diagram

The diagram below should be adhered to strictly, lest you risk damaging the device. The diagram is a representation of the device as seen from the side where the terminals are exposed (their screws).

Placement Guidelines

The device is intended for installation in console boxes, panels and in places that provide an insulating shell of at least 5mm to cover current-carrying parts or other conductive parts!

The device must be mounted to non-conductive surfaces!

The device must be installed in a place that ensures good cooling. Install vertically for improved cooling!

To be used only as a control device and not as a protection device!

If you have any questions, feel free to reach out to us at lorawan-support@mclimate.eu

🆕
Smart Buildings - Scalable LoRaWAN & NB-IoT Solutions by MClimateMClimate
894KB
16ADS-User-Manual.pdf
pdf
User Manual
889KB
16ADS-LoRaWAN-Mounting-Instructions.pdf
pdf
Mounting Instructions
988KB
MClimate-16ADS-Datasheet.pdf
pdf
Datasheet
16ADS Wiring diagram
Logo