# Commands cheat sheet

A clean cheat sheet for those who are already familiar with the communication protocol of the device.

{% hint style="info" %}
The **Command name** is a clickable link that takes you to the specific command section in the document.
{% endhint %}

<table data-header-hidden><thead><tr><th width="126.33333333333331"></th><th width="106"></th><th width="384"></th><th></th></tr></thead><tbody><tr><td><strong>Command code, [HEX]</strong></td><td><strong>Firmware version</strong></td><td><strong>Command name</strong></td><td><strong>Sent by</strong></td></tr><tr><td>01</td><td>All</td><td><a href="/pages/SAcmX3GZxCgPjUWrIeAc"><strong>Keep-alive</strong></a></td><td>End device</td></tr><tr><td>02</td><td>All</td><td><a href="/pages/SAcmX3GZxCgPjUWrIeAc#this-command-is-used-to-set-the-fcts-keep-alive-message-period-the-keep-alive-data-in-the-example-is"><strong>Set keep-alive period</strong></a></td><td>Server</td></tr><tr><td>03</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#you-can-set-the-target-temperature-step-with-the-command"><strong>Set target temperature step</strong></a></td><td>Server</td></tr><tr><td>04</td><td>All</td><td><a href="/pages/5l9X0wUYW2SjR0Tg2G9q#get-firmware-and-hardware-version"><strong>Read device hardware and software version</strong></a></td><td>Server/ End device</td></tr><tr><td>05</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#this-command-gets-the-target-temperature-step.-the-keepalive-data-in-the-example-below-is-omitted-fo"><strong>Get target temperature step</strong></a></td><td>Server/ End device</td></tr><tr><td>07</td><td>All</td><td><a href="/pages/hzFxyZIhAIQeO4FJCaK7#you-can-disable-one-or-a-combination-of-keys-with-the-command"><strong>Set keys locked</strong></a></td><td>Server</td></tr><tr><td>08</td><td>≤ 1.5 and ≥ 1.8</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#set-6"><strong>Set target temperature range</strong></a></td><td>Server</td></tr><tr><td>10</td><td>All</td><td><a href="/pages/XyW1qGQ2Ovj3uIjOIqe1#this-command-is-used-to-set-the-period-t-of-lorawan-join-request-sending-from-the-end-node-device.-t"><strong>Set network join retry period</strong></a></td><td>Server</td></tr><tr><td>11</td><td>All</td><td><a href="/pages/RuMgbeRzfXPrtCl4fZAf#this-command-is-used-to-set-fan-coil-thermostat-uplink-message-type."><strong>Set uplink messages type</strong></a></td><td>Server</td></tr><tr><td>12</td><td>All</td><td><a href="/pages/SAcmX3GZxCgPjUWrIeAc#this-command-is-used-to-get-the-fcts-keep-alive-message-period-the-keep-alive-data-in-the-example-is"><strong>Get keep-alive period</strong></a></td><td>Server/ End device</td></tr><tr><td>14</td><td>All</td><td><a href="/pages/hzFxyZIhAIQeO4FJCaK7#this-command-gets-which-keys-have-been-disabled."><strong>Get keys locked</strong></a></td><td>Server/ End device</td></tr><tr><td>15</td><td>≤ 1.5 and ≥ 1.8</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#get-6"><strong>Get target temperature range</strong></a></td><td>Server/ End device</td></tr><tr><td>16</td><td>≥ 1.6</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#set-2"><strong>Set heating and cooling target temp. ranges</strong></a></td><td>Server</td></tr><tr><td>17</td><td>≥ 1.6</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#get-2"><strong>Get heating and cooling target temp. ranges</strong></a></td><td>Server/ End device</td></tr><tr><td>19</td><td>All</td><td><a href="/pages/XyW1qGQ2Ovj3uIjOIqe1#this-command-is-used-to-get-the-period-t-of-lorawan-join-request-sending-from-the-end-node-device.-t"><strong>Get network join retry period</strong></a></td><td>Server/ End device</td></tr><tr><td>1B</td><td>All</td><td><a href="/pages/RuMgbeRzfXPrtCl4fZAf#this-command-is-used-to-get-fan-coil-thermostat-uplink-messages-type."><strong>Get uplink messages type</strong></a></td><td>Server/ End device</td></tr><tr><td>1C</td><td>All</td><td><a href="/pages/XyW1qGQ2Ovj3uIjOIqe1#this-command-is-used-to-set-independent-radio-watch-dog-configurations-for-confirmed-and-unconfirmed"><strong>Set device radio communication watch-dog parameters</strong></a></td><td>Server</td></tr><tr><td>1D</td><td>All</td><td><a href="/pages/XyW1qGQ2Ovj3uIjOIqe1#this-command-is-used-to-get-the-radio-watch-dog-configurations."><strong>Get device radio communication watch-dog parameters</strong></a></td><td>Server/ End device</td></tr><tr><td>2E</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#you-can-set-the-target-temperature-with-the-command"><strong>Set target temperature</strong></a></td><td>Server</td></tr><tr><td>2F</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#this-command-gets-the-target-temperature.-the-keepalive-data-in-the-example-below-is-omitted-for-cla"><strong>Get target temperature</strong></a></td><td>Server/ End device</td></tr><tr><td>30</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#manual-change-from-the-thermostats-buttons"><strong>Manual target temperature change</strong></a></td><td>End device</td></tr><tr><td>31</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#set-the-valve-open-time."><strong>Set valve open/ close time</strong></a></td><td>Server</td></tr><tr><td>32</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#get-the-valve-open-time."><strong>Get valve open/ close time</strong></a></td><td>Server/ End device</td></tr><tr><td>33</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#this-command-sets-the-full-display-refresh-period."><strong>Set full display refresh period</strong></a></td><td>Server</td></tr><tr><td>34</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#this-command-gets-the-full-display-refresh-period."><strong>Get full display refresh period</strong></a></td><td>Server/ End device</td></tr><tr><td>35</td><td>All</td><td><a href="/pages/95L0343nBNIADdo9uJzu#this-command-activates-deactivates-the-automatic-temp.-control-mode-with-external-temp.-reading."><strong>Set automatic temperature control mode with external temperature reading</strong></a></td><td>Server</td></tr><tr><td>36</td><td>All</td><td><a href="/pages/95L0343nBNIADdo9uJzu#this-command-gets-whether-automatic-temp.-control-mode-with-external-temp.-reading-is-enabled-or-dis"><strong>Get automatic temperature control mode with external temperature reading</strong></a></td><td>Server/ End device</td></tr><tr><td>3B</td><td>All</td><td><a href="/pages/95L0343nBNIADdo9uJzu#2.1-set-external-temperature-sensor-value-with-resolution-1.0-c"><strong>Set external temperature sensor value with resolution 1°C</strong></a></td><td>Server</td></tr><tr><td>3C</td><td>All</td><td><a href="/pages/95L0343nBNIADdo9uJzu#you-can-set-the-external-temperature-with-the-command"><strong>Set external temperature sensor value with resolution 0.1°C</strong></a></td><td>Server</td></tr><tr><td>3E</td><td>All</td><td><a href="/pages/95L0343nBNIADdo9uJzu#when-the-fan-coil-thermostat-is-in-automatic-temperature-control-mode-with-external-temperature-read"><strong>Get external temperature sensor value with resolution 0.1°C</strong></a></td><td>Server/ End device</td></tr><tr><td>40</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#this-command-shows-hides-the-measured-temperature-on-the-display."><strong>Set flag show/hide measured temperature</strong></a></td><td>Server</td></tr><tr><td>41</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#check-whether-the-measured-temperature-is-shown-hidden."><strong>Get flag show/hide measured temperature</strong></a></td><td>Server/ End device</td></tr><tr><td>42</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#this-command-shows-hides-the-measured-humidity-on-the-display."><strong>Set flag show/hide humidity</strong></a></td><td>Server</td></tr><tr><td>43</td><td>All</td><td><a href="/pages/a6svEWE5ofQPdPZEY9bg#check-whether-the-measured-temperature-is-shown-hidden.-1"><strong>Get flag show/hide humidity</strong></a></td><td>Server/ End device</td></tr><tr><td>44</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#you-can-set-the-fan-speed-with-the-command"><strong>Set fan speed</strong></a></td><td>Server</td></tr><tr><td>45</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#this-command-gets-the-ecm-fan-speed.-the-keepalive-data-in-the-example-below-is-omitted-for-clarity."><strong>Get fan speed</strong></a></td><td>Server/ End device</td></tr><tr><td>46</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#you-can-set-the-fan-speed-limit-with-the-command"><strong>Set fan speed limit</strong></a></td><td>Server</td></tr><tr><td>47</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#this-command-gets-the-target-temperature.-the-keepalive-data-in-the-example-below-is-omitted-for-cla"><strong>Get fan speed limit</strong></a></td><td>Server/ End device</td></tr><tr><td>48</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#the-command-adjusts-the-voltage-range-of-the-ecm-fan."><strong>Set ECM fan min/max voltage</strong></a></td><td>Server</td></tr><tr><td>49</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#the-command-extracts-the-voltage-range-of-the-ecm-fan."><strong>Get ECM fan min/max voltage</strong></a></td><td>Server/ End device</td></tr><tr><td>4A</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#set-up-the-the-start-up-time."><strong>Set ECM fan start up time</strong></a></td><td>Server</td></tr><tr><td>4B</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#get-up-the-the-start-up-time."><strong>Get ECM fan start up time</strong></a></td><td>Server/ End device</td></tr><tr><td>4C</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#set-the-ecm-relay-to-activated-deactivated."><strong>Set ECM fan Relay (F-ON) - activated/deactivated</strong></a></td><td>Server</td></tr><tr><td>4D</td><td>All</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#get-the-status-of-the-ecm-relay."><strong>Get ECM fan Relay (F-ON) - activated/deactivated</strong></a></td><td>Server/ End device</td></tr><tr><td>4E</td><td>All</td><td><a href="/pages/vwNkLRkz9FmdEAYtwb5m#set-the-frost-protection-status."><strong>Set frost protection status - ON/OFF</strong></a></td><td>Server</td></tr><tr><td>4F</td><td>All</td><td><a href="/pages/vwNkLRkz9FmdEAYtwb5m#get-the-frost-protection-status."><strong>Get frost protection status  - ON/OFF</strong></a></td><td>Server/ End device</td></tr><tr><td>50</td><td>All</td><td><p><a href="/pages/vwNkLRkz9FmdEAYtwb5m#set-the-frost-protection-set-point-and-threshold."><strong>Set frost protection threshold and setpoint temperatures</strong></a></p><p></p></td><td>Server</td></tr><tr><td>51</td><td>All</td><td><a href="/pages/vwNkLRkz9FmdEAYtwb5m#get-the-frost-protection-set-point-and-threshold."><strong>Get frost protection threshold and setpoint temperatures</strong></a></td><td>Server/ End device</td></tr><tr><td>52</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#you-can-set-the-operational-mode-with-the-command"><strong>Set operation mode</strong></a></td><td>Server</td></tr><tr><td>53</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#this-command-gets-the-operational-mode."><strong>Get operation mode</strong></a></td><td>Server/ End device</td></tr><tr><td>54</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#you-can-set-the-allowed-operational-mode-with-the-command"><strong>Set allowed operating modes</strong></a></td><td>Server</td></tr><tr><td>55</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#this-command-gets-the-allowed-operating-mode."><strong>Get allowed operating modes</strong></a></td><td>Server/ End device</td></tr><tr><td>56</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#set"><strong>Set cooling set-point unoccupied</strong></a></td><td>Server</td></tr><tr><td>57</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#get"><strong>Get cooling set-point unoccupied</strong></a></td><td>Server/ End device</td></tr><tr><td>58</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#set-1"><strong>Set heating set-point unoccupied</strong></a></td><td>Server</td></tr><tr><td>59</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#get-1"><strong>Get heating set-point unoccupied</strong></a></td><td>Server/ End device</td></tr><tr><td>5A</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#this-command-is-used-to-set-the-compensation-temperature-values."><strong>Set sensor compensation temperature</strong></a></td><td>Server</td></tr><tr><td>5B</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#this-command-is-used-to-get-the-compensation-temperature-values."><strong>Get sensor compensation temperature</strong></a></td><td>Server/ End device</td></tr><tr><td>5C</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#you-can-set-the-fan-speed-with-the-command"><strong>Set fan speed not occupied</strong></a></td><td>Server</td></tr><tr><td>5D</td><td>All</td><td><a href="/pages/siBgbUXGAFl5EtbJOlAq#this-command-gets-the-target-temperature.-the-keepalive-data-in-the-example-below-is-omitted-for-cla"><strong>Get fan speed not occupied</strong></a></td><td>Server/ End device</td></tr><tr><td>5E</td><td>All</td><td><a href="/pages/Rig2wa3QlsjLo5fY8WSa#the-command-enables-disables-automatic-changeover."><strong>Set automatic changeover status - on/off</strong></a></td><td>Server</td></tr><tr><td>5F</td><td>All</td><td><a href="/pages/Rig2wa3QlsjLo5fY8WSa#get-the-automatic-changeover-status."><strong>Get automatic changeover status - on/off</strong></a></td><td>Server/ End device</td></tr><tr><td>60</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#you-can-set-the-target-applications-with-the-command"><strong>Set application</strong></a></td><td>Server</td></tr><tr><td>61</td><td>All</td><td><a href="/pages/LrDvnleUNEDXSTLCSOdZ#this-command-gets-the-application.-the-keepalive-data-in-the-example-below-is-omitted-for-clarity."><strong>Get application</strong></a></td><td>Server/ End device</td></tr><tr><td>62</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-set-the-function-of-digital-input-output-occ-with-the-command"><strong>Set function of digital input/output (OCC)</strong></a></td><td>Server</td></tr><tr><td>63</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#this-command-gets-the-heating-setpoint.-the-keepalive-data-in-the-example-below-is-omitted-for-clari"><strong>Get function of digital input/output (OCC)</strong></a></td><td>Server/ End device</td></tr><tr><td>64</td><td>All</td><td><a href="/pages/Rig2wa3QlsjLo5fY8WSa#this-command-is-used-to-set-the-threshold-changeover-temperatures-values."><strong>Set automatic changeover threshold temperature</strong></a></td><td>Server</td></tr><tr><td>65</td><td>All</td><td><a href="/pages/Rig2wa3QlsjLo5fY8WSa#this-command-is-used-to-get-the-threshold-changeover-temperatures."><strong>Get automatic changeover threshold temperature</strong></a></td><td>Server/ End device</td></tr><tr><td>66</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#set-the-status-of-the-device."><strong>Set device status - on/off</strong></a></td><td>Server</td></tr><tr><td>67</td><td>All</td><td><a href="/pages/kDqx5fDt6kK7a8ClqGmC#get-the-status-of-the-device."><strong>Get device status - on/off</strong></a></td><td>Server/ End device</td></tr><tr><td>68</td><td>All</td><td><a href="/pages/5l9X0wUYW2SjR0Tg2G9q#you-can-set-the-operation-after-return-of-power-supply-with-the-command"><strong>Set operation after return of power supply</strong></a></td><td>Server</td></tr><tr><td>69</td><td>All</td><td><a href="/pages/5l9X0wUYW2SjR0Tg2G9q#get-the-operation-after-return-to-power-status."><strong>Get operation after return of power supply</strong></a></td><td>Server/ End device</td></tr><tr><td>6A</td><td>All</td><td><a href="/pages/DWG8Ihq9iQsonSrRf2T8#you-can-set-the-delta-temperature-dt1-with-the-command"><strong>Set delta temperature 1 (ΔT1)</strong></a></td><td>Server</td></tr><tr><td>6B</td><td>All</td><td><a href="/pages/DWG8Ihq9iQsonSrRf2T8#this-command-gets-the-target-temperature-step.-the-keepalive-data-in-the-example-below-is-omitted-fo"><strong>Get delta temperature 1 (ΔT1)</strong></a></td><td>Server/ End device</td></tr><tr><td>6C</td><td>All</td><td><a href="/pages/DWG8Ihq9iQsonSrRf2T8#you-can-set-the-delta-temperatures-dt1-and-dt3-with-the-command"><strong>Set delta temperature 2 (ΔT2) and 3 (ΔT3)</strong></a></td><td>Server</td></tr><tr><td>6D</td><td>All</td><td><a href="/pages/DWG8Ihq9iQsonSrRf2T8#this-command-gets-the-target-temperature-step.-the-keepalive-data-in-the-example-below-is-omitted-fo-1"><strong>Get delta temperature 2 (ΔT2) and 3 (ΔT3)</strong></a></td><td>Server/ End device</td></tr><tr><td>6E</td><td>All</td><td><a href="/pages/vwNkLRkz9FmdEAYtwb5m#you-can-read-the-frost-protection-status-with-the-command"><strong>Get frost protection status</strong></a></td><td>Server/ End device</td></tr><tr><td>70</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-read-the-occupancy-sensor-status-with-the-command"><strong>Get occupancy sensor status (set-point decrease)</strong></a></td><td>Server/ End device</td></tr><tr><td>71</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-read-the-occupancy-sensor-status-with-the-command-1"><strong>Get occupancy sensor status (fan off, valve closed)</strong></a></td><td>Server/ End device</td></tr><tr><td>72</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-read-the-dew-point-sensor-status-with-the-command"><strong>Get dew point sensor status</strong></a></td><td>Server/ End device</td></tr><tr><td>73</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-read-the-filter-alarm-status-with-the-command"><strong>Get filter alarm status</strong></a></td><td>Server/ End device</td></tr><tr><td>74</td><td>All</td><td><a href="/pages/AhLPeULGjn5lVMudgSfS#you-can-read-the-mode-changed-by-the-changeover-function-end-external-ntc-sensor-temperature-with-th"><strong>Get mode changed by the auto changeover function</strong></a></td><td>Server/ End device</td></tr><tr><td>75</td><td>All</td><td><a href="/pages/EKJzqPpuuJVEjU5kFzCy"><strong>Get power module communication status</strong></a></td><td>Server/ End device</td></tr><tr><td>76</td><td>≥ 1.6</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#set-2"><strong>Set heating and cooling target temp. ranges - unoccupied</strong></a></td><td>Server</td></tr><tr><td>77</td><td>≥ 1.6</td><td><a href="/pages/CQRYUDHEvaBEena2qR8f#get-2"><strong>Get heating and cooling target temp. ranges - unoccupied</strong></a></td><td>Server/ End device</td></tr><tr><td>78</td><td>≥ 1.6</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#set-7"><strong>Set fan off delay time</strong></a></td><td>Server</td></tr><tr><td>79</td><td>≥ 1.6</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#get-7"><strong>Get fan off delay time</strong></a></td><td>Server/ End device</td></tr><tr><td>7A</td><td>≥ 1.6</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#set-6"><strong>Set additional fan modes</strong></a></td><td>Server</td></tr><tr><td>7B</td><td>≥ 1.6</td><td><a href="/pages/ti1RWwMIrTlgUzkDO9th#get-6"><strong>Get additional fan modes</strong></a></td><td>Server/ End device</td></tr><tr><td>7C</td><td>≥ 1.9</td><td><a href="/pages/fs2SBHHG9ukEAwSc50eZ#get-internal-temperature-sensor-error"><strong>Get internal temperature sensor error</strong></a></td><td>Server/ End device</td></tr><tr><td>7D</td><td>≥ 1.9</td><td><a href="/pages/fs2SBHHG9ukEAwSc50eZ#get-external-temperature-sensor-error"><strong>Get external temperature sensor error</strong></a></td><td>Server/ End device</td></tr><tr><td>9A</td><td>≥ 1.8</td><td><a href="/pages/CJeBBJWgbCMY38vBqoFm#set"><strong>Set user interface language</strong></a></td><td>Server</td></tr><tr><td>9B</td><td>≥ 1.8</td><td><a href="/pages/CJeBBJWgbCMY38vBqoFm#get"><strong>Get user interface language</strong></a></td><td>Server/ End device</td></tr><tr><td>A4</td><td>≥ 1.4</td><td><a href="/pages/XyW1qGQ2Ovj3uIjOIqe1#get-lorawan-region"><strong>Get</strong> <strong>LoRaWAN Region</strong></a></td><td>Server/ End device</td></tr><tr><td>A5</td><td>≥ 1.8</td><td><a href="/pages/NIAYpZEzjzw5NUUysA0J"><strong>Restart device</strong></a></td><td>Server</td></tr></tbody></table>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.mclimate.eu/mclimate-lorawan-devices/devices/mclimate-fan-coil-thermostat-fct/mclimate-fan-coil-thermostat-device-communication-protocol/commands-cheat-sheet.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.